Decorative round surface-mounted luminaire for indoor and outdoor use. Base: pressure die-cast aluminium, powder-coated. Standard Gore™ Protective Vents diaphragm valve to avoid condensation. Uniform lighting achieved by the use of LED panel boards. Suitable for Ceiling mounting, Wall (surface). Very easy installation thanks to plug & play connection. The large connection compartment on the back for convenient connections is also ideal for through wiring. Electronic ballast included. Self-contained system with automatic self-test and feedback via DALI bus, only to RZB DALI monitoring system.
Technical Specifications
Typ of emergency lighting | Self-contained system |
---|---|
Monitoring | DALI-Sibe |
Battery | LiFePO4 |
Duration | 8 h |
Operating mode | maintained power mode |
Diameter D | 450 mm |
Height H | 70 mm |
Weight | 4.7 kg |
Light source | LED |
Colour temperature | 3000 K | 4000 K |
Rated luminous flux, mains operation |
3000 K: 2450 lm | 4000 lm 4000 K: 2550 lm | 4150 lm |
System power, mains operation |
3000 K: 26 W | 41 W 4000 K: 26 W | 41 W |
Rated luminous flux, emergency operation | 150 lm |
System efficiency |
3000 K: 94 lm/W | 98 lm/W 4000 K: 98 lm/W | 101 lm/W |
Glare evaluation RUG (4H 8H) |
3000 K: 20,5 | 22,2 4000 K: 20,6 | 22,3 |
Beam angle |
down 126° up 180° |
Rated life | 50000 h |
Colour rendering index (CRI) | 80 |
Photobiological safety according to EN 62471 | Risk group 1 |
Driver | Converter |
Control | on/off |
Voltage | 220 - 240 V / 50 Hz, 60 Hz |
Luminaires on B10A fuse | 31 |
Luminaires on B16A fuse | 50 |
Luminaires on C10A fuse | 52 |
Luminaires on C16A fuse | 85 |
Inrush current / Inrush current duration | 5 A / 50 µs |
CIE Flux Code / CEN Flux Code | 41 71 90 79 100 |
Type of protection | IP 65 |
Protection class | I |
Filament test | 960 °C |
Impact resistance | IK03 |
Ambient temperature for maintained power | 5 °C ... + 25 °C |
Safety marks | D-mark |
Conformity mark | CE , EAC |
Downloads
Light Calculator
The Online Light Calculator's purpose is a quick calculation and the results may not be perfectly accurate.