Rapid-installation complete module for universal use as a continuous line luminaire. Light division (1=LED, 0= blank): 1100. System profile made of aluminium extrusion profile, anodised. High-efficiency LED units with optimum light control thanks to clear plastic (PC) lens optics. Blank units with cover made of plastic, surface like housing. Light distribution deep-wide beam. Simple, tool-free installation of system profiles using separate accessories for cable, chain or ceiling suspension. Tool-free connection and mechanical connectors to secure. 14-poles LINEDO connector (5 x 2.5 mm² / 9 x 1.5 mm²) for additional applications in light management or for the integration of emergency lighting. Phase can be set via patended bridge without opening the luminaire. Please order supply module, connection and mounting accessories separately. Luminaire with limited surface temperature in accordance with EN 60598-2-24 for use in environments in which a deposit of non-conductive dust on the luminaire can be expected.
Technical Specifications
Length L | 2291 mm |
---|---|
Width B | 58 mm |
Height H | 76 mm |
Weight | 5.25 kg |
Light source | LED |
Colour temperature | 4000 K |
Rated luminous flux | 3350 lm |
System power | 21 W |
System efficiency | 160 lm/W |
Glare evaluation RUG (4H 8H) | 17 |
Beam angle | 59° |
Rated life | 80000 h (L80/B10) |
Colour rendering index (CRI) | 80 |
Colour tolerance (McAdam) | 3 SDCM |
Photobiological safety according to EN 62471 | Risk group 1 |
Driver | Converter, dimmable |
Control | DALI |
Voltage | 220 - 240 V / 0 Hz, 50 - 60 Hz |
Luminaires on B10A fuse | 23 |
Luminaires on B16A fuse | 36 |
Luminaires on C10A fuse | 38 |
Luminaires on C16A fuse | 61 |
Inrush current / Inrush current duration | 5 A / 870 µs |
CIE Flux Code / CEN Flux Code | 86 96 99 100 100 |
Type of protection | IP 54 |
Protection class | I |
Filament test | 650°C - 30 seconds |
Impact resistance | IK03 |
Ambient temperature | -25 °C bis + 50 °C |
Safety marks | D-mark |
Conformity mark | CE |
Downloads
Light Calculator
The Online Light Calculator's purpose is a quick calculation and the results may not be perfectly accurate.