Luminaire for escape route illumination. Housing and end caps made of sheet steel, powder coated. End caps with hidden screws, with permanently dimensionally stable silicone foam seal. Curved diffuser made of non-yellowing plastic (PMMA), opal. Specially matched 2-component optical system for homogeneous and soft illumination of the entire light-emitting surface. Suitable for Ceiling mounting, Wall (surface). Self-contained system with automatic self-test and feedback to the RZB monitoring system MULTIDIGIT. Luminaire with limited surface temperature in accordance with EN 60598-2-24 for use in environments in which a deposit of non-conductive dust on the luminaire can be expected.
Technical Specifications
Typ of emergency lighting | Self-contained system |
---|---|
Monitoring | MultiDigit |
Battery | LiFePO4 |
Duration | 3 h |
Operating mode | maintained power mode |
Length L | 320 mm |
Width B | 160 mm |
Height H | 58 mm |
Weight | 1.7 kg |
Light source | LED |
Colour temperature | 4000 K |
Rated luminous flux, mains operation | 590 lm |
System power, mains operation | 7,5 W |
Rated luminous flux, emergency operation | 310 lm |
System efficiency | 79 lm/W |
Glare evaluation RUG (4H 8H) | 21,2 |
Beam angle |
down 127°/116° up 180°/180° |
Rated life | 50000 h |
Colour rendering index (CRI) | 80 |
Photobiological safety according to EN 62471 | Risk group 1 |
Driver | Converter |
Control | on/off |
Voltage | 220 - 240 V / 50 Hz, 60 Hz |
Luminaires on B10A fuse | 17 |
Luminaires on B16A fuse | 27 |
Luminaires on C10A fuse | 28 |
Luminaires on C16A fuse | 45 |
Inrush current / Inrush current duration | 27 A / 250 µs |
CIE Flux Code / CEN Flux Code | 42 73 91 93 100 |
Type of protection |
IP 54 ceiling mounting IP 50 wall mounting |
Protection class | I |
Filament test | 650 °C |
Impact resistance | IK05 |
Ambient temperature for maintained power | 0 °C ... + 35 °C |
Ambient temperature for non-maintained power mode | 5 °C ... + 40 °C |
Safety marks | D-mark |
Conformity mark | CE |
Downloads
Light Calculator